XLSCB surge protector
Non-trip impulse current le(820μs) 10kA、20kA、40kA、60kA、80kA、100kA、120kA、160kA Non-trip impulse current le(10350μs) 15kA、25kA Rated operating voltage Ue 230/400VAC Current trip value lo 3±1A Power frequency short circuit current breaking time Tos ≤ 40ms Power frequency load current breaking time To ≤ 50ms Normal working environment -25~+60℃ Installation mode 35mm standard card rails Number of poles 2P、3P、4P Dimensions and mounting dimensions (mm) 85×36×73.5(2P) 85×72×73.5(3P、4P)
-
SP9-I surge protector
Rated operating voltage (Un) 230V/400V Nominal discharge current In(820μs) 50kA、50kA、50kA Impulse current Iimp(10350μs) 15kA、25kA、50kA Large continuous operating voltage (Uc) 275V、 320V、 385V、 440V 、275V、 320V、 385V、 440V、275V 、385V Voltage protection level (Up)kV <1.5、 <1.6 、<2.0 、<2.2、 <1.8 、<2.0、 <2.2、 <2.4、 <2.3、 <2.5 Large continuous operating voltage (Uc) 385V Test classification Level I Class of protection IP20 class Installation mode 35mm standard card rails Number of poles 1P 2P 3P 4P Dimensions and mounting dimensions (mm) 90×36×64 90×72×64 90×108×64 90×144×64
-
SP7 surge protector
Rated operating voltage (Un) 230V/400V Nominal discharge current In(820μs) 40kA、50kA、60kA、100kA Large discharge current Imax(820μs) 80kA、100kA、120kA、160kA Large continuous operating voltage (Uc) 385V、420V Protection level (Up)kV <2.4、 <2.5、 <2.5、<2.8、 <2.8、 <3.0 、<3.0 、<3.5 Leakage current (75%Uc1mA) <20μA Test classification Level II Class of protection IP20 class A fuse or circuit breaker is recommended 50A、63A、100A Installation mode 35mm standard card rails Number of poles 1P 2P 3P 4P Dimensions and mounting dimensions (mm) 90×36×64 90×72×64 90×108×64 90×144×64
-
SP1-NPE surge protector
Rated operating voltage (Un) 230V、400V Nominal discharge current In(820μs) 5kA、10kA、20kA、30kA、40kA、60kA Maximum discharge current Imax(8/20μs) 10kA、20kA、40kA、60kA、80kA、100kA Maximum continuous operating Voltage (Uc) 255V Protection level (Up)kV <1.0、 <1.1、 <1.2 、<1.5 、<1.7 、<2.0 Leakage current (75%Uc1mA) <20μA Test classification Level II Class of protection IP20 class A fuse or circuit breaker is recommended 10~16A、40A~63A Installation mode 35mm standard card rails Number of poles 1P+N
3P+N
Dimensions and mounting dimensions (mm) 90×36×67
90×54×6790×72×67
90×108×67
-
SP1-B surge protector
Protection level Primary protection Rated operating voltage (Un) 230V/400V Nominal discharge current In(820μs) 30kA、40kA、60KA Large discharge current Imax(820μs) 60kA、80kA、100kA Large continuous operating voltage (Uc) 320V、385V、420V、 440V、 320V、 385V、 420V、 440V、 320V、 385V、 420V、 440V Protection level (Up)kV <2.0、<2.2、 <2.2、 <2.4、 <2.2、 <2.5、 <2.5、 <2.7、 <2.5 、<2.5 、<3.0、 <3.2 Leakage current (75%Uc1mA) <20μA Test classification Level II Class of protection IP20 class A fuse or circuit breaker is recommended 40A~63A Installation mode 35mm standard card rails Number of poles 1P 2P 3P 4P Dimensions and mounting dimensions (mm) 90×27×67 90×54×67 90×81×67 90×108×67
-
SP1-C surge protector
Protection level Secondary protection Rated operating voltage (Un) 230V/400V Nominal discharge current In(820μs) 20kA Large discharge current Imax(820μs) 40kA Large continuous operating voltage (Uc) 275V、320V、385V、420V、440V Protection level (Up)kV <1.5 、<1.6 、<1.8 、<2.0 、<2.2 Leakage current (75%Uc1mA) <20μA Test classification Level II Class of protection IP20 class A fuse or circuit breaker is recommended 40A~63A Installation mode 35mm standard card rails Number of poles 1P 2P 3P 4P Dimensions and mounting dimensions (mm) 90×18×67 90×36×67 90×54×67 90×72×67
-
SP1-D surge protector
Protection level Tertiary protection Rated operating voltage (Un) 230V/400V Nominal discharge current In(820μs) 5kA、10kA Large discharge current Imax(820μs) 10kA、20kA Large continuous operating voltage (Uc) 275V、 320V 、385V、 420V、 275V、 320V 、385V、 420V Protection level (Up)kV <1.0、<1.2 、<1.2 、<1.2、 <1.2 、<1.5、<1.5、<1.5 Leakage current (75%Uc1mA) < 20μA Test classification Level II Class of protection IP20 class A fuse or circuit breaker is recommended 10A~16A Installation mode 35mm standard card rails Number of poles 1P 2P 3P 4P Dimensions and mounting dimensions (mm) 90×18×67 90×36×67 90×54×67 90×72×67
Hot product / Hot Products
Recommendation information / Recommended News
The research team of the United Front Work Department of the CPC Yueqing Municipal Committee visited Devil's 13 Electric to carry out a special research on "Two health" culture
-
The research team of the United Front Work Department of the CPC Yueqing Municipal Committee visited Devil's 13 Electric to carry out a special research on "Two health" culture
On October 17, Zheng Juhua, member of the Standing Committee of Yueqing Municipal Committee and Minister of the United Front Work Department, and Ye Rupeng, vice minister of the United Front Work Department, visited Devil's 13 Electric to carry out a cultural research on "two health". Hu Zhixing, chairman of Devil's 13 Electric, and Huit, vice president of Devil's 13, accompanied the research. 【 More details 】
- 2019-06-15 Jing Lingling, vice chairman of Jiexue CPPCC, visited Devil's 13 electrical research
- 2018-05-12 Wang Xiaochun, deputy director of Policy Research Office of Wenzhou Municipal Committee, visited Devil's 13 company for research and guidance
- 2019-11-27 Brave to say "no" in the face of domestic violence |Devil's 13 Electric held a special lecture on "Opposing domestic violence and Building a harmonious Society"
- 2020-05-29 Focus on "smart" industrial transformation and upgrading 2.0| Lu Jianbo, deputy director of Industrial transformation and Upgrading Department of Provincial Economy and Information Technology Department, visited the survey
- 2019-11-05 Devil's 13 company successfully held the "Made in Zhejiang" group standard launch and seminar
- 2016-07-11 Devil's 13 Electrical Brief introduction to the development trend of low-voltage electrical appliance industry
- 2019-12-17 Let love grow with "xin" care |Devil's 13 Electric held a charity sale for caring special education children
- 2018-12-08 Bao Xiaoou, vice chairman of Wenzhou CPPCC, visited Devil's 13 Electric
- 2018-11-13 Devil's 13 event Express: The first game of tug-of-war, Jedi second kill, storm reversal! Who can break through and advance?
- 2019-10-29 And Devil's 13 to go on a trip | drop ~ front to the station - Jiangsu station!
Devil's 13 Product Center
relay
sensor
Switch
Electric drive and control
blaze apostas
Distribution control
- Miniature circuit breaker
- Ac contactor
- The surge protector
- Plastic-case circuit breaker
- Universal circuit breaker
- Dual power automatic change-over switchgear
- Thermal overload relay
- Load disconnecting switch
- Control and protection switch series
Switching power supply and power module
C series
Hot selling recommendation
New product display
Product certificate
Old model
cqc
cqc
Automation industry application
Application case
Contact Devil's 13Contact
Hotline:400-8236-775
Phone:0577-6273 5555
Fax:0577-6272 2963
Email:[email protected]
Company Address:No. 328, Wei19 Road, Yueqing Economic Development Zone, Zhejiang